节点文献

改进倒置A~2/O工艺处理生活污水试验研究

Improved inverted A~2/O process for sewage treatment

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王琪刘年丰张杰丁峰

【Author】 Wang Qi1,Liu Nianfeng1,Zhang Jie1,Ding Feng2. (1.Huazhong University of Science & Technology,Wuhan Hubei 430074;2.Hezhou Environmental Monitoring Station,Hezhou Guangxi 542800)

【机构】 华中科技大学环境学院贺州市环境监测站 湖北武汉430074湖北武汉430074广西贺州542800

【摘要】 对倒置A2/O工艺进行了缺氧池生物挂膜实验,结果表明,在化粪池出水COD有一定波动情况下,缺氧池COD去除率不仅较高且较稳定,有利于后续硝化反应的进行,提高系统的脱氮效果。同时研究了C/N在缺氧池中对脱氮效果的影响,C/N(质量比)>8.0脱氮效率达80%以上,C/N<6.0脱氮效果较差,证实了C/N是影响反硝化的关键因素。系统进水COD不高,影响了去除效果。

【Abstract】 Addition of bio-film carriers to allow attached growth in the anoxic tank of the inverted A2/O treatment system resulted in a more stable effluent with a lower COD,especially during the period when the feed COD concentration was highly variable. It also enhanced nitrification in the aerobic tank and thus improved the system’s capability of total nitrogen (TN) removal.A high C/N feed was essential for effective denitrification and for high TN removal. The improved inverted A2/O process removed > 80% of TN in the feed with a C/N of >8.0, the TN removal was much lower when the feed C/N was <6.0. Because of the low total phosphorousin the feed (TP<3 mg/L) and also the high COD removal achieved in the anoxic tank,no significant improvement in the overall TP removal was observed.

【基金】 国家“863”计划资助项目(No2002AA601022-4-2)
  • 【文献出处】 环境污染与防治 ,Environmental Pollution & Control , 编辑部邮箱 ,2007年05期
  • 【分类号】X703
  • 【被引频次】18
  • 【下载频次】429
节点文献中: 

本文链接的文献网络图示:

本文的引文网络