节点文献

两级曝气生物滤池工艺的小试研究

Experimental Study on Technique of Two-Stage Biological Aerated Filter

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【摘要】 对两级曝气生物滤池(上向流-下向流)处理生活污水进行了试验研究。试验表明,两级曝气生物滤池在水力负荷小于4m/h,进水COD浓度变化范围为100~500mg/L,一级气水比为3∶1~5∶1,二级气水比为1∶1~2∶1的条件下,出水水质稳定,出水水质达到生活杂用水水质标准。

【Abstract】 This paper focused on the experimental study on the Two-stage Biological Aerated Filter(up-flow and down-flow) for municipal wastewater treatment.The results show that the effluent quality is acceptable and can meet the requirements of the water quality standard for domestic miscellaneous uses when the hydraulic loading less than 4m/h and the inlet COD content is between 100~500mg/L with the first stage air-water ratio being 3∶1~5∶1 and the second stage being 1∶1 ~2∶1.

  • 【文献出处】 环境保护科学 ,Environmental Protection Science , 编辑部邮箱 ,2007年04期
  • 【分类号】X703
  • 【被引频次】4
  • 【下载频次】143
节点文献中: 

本文链接的文献网络图示:

本文的引文网络