曝气生物滤池在污水回用中的挂膜启动试验研究

Research on the start-up of biological aerated filter in water reuse

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 傅金祥许海良赵玉华孙钦敏王秋鸿

【Author】 Fu Jinxiang1,Xu Hailiang1,Zhao Yuhua1,Sun Qinmin2,Wang Qiuhong2(1.School of Municipal and Environmental Engineering,Shenyang Construction University,Shenyang 110168,China;2.North Sewage Treatment Plant of Shenyang,Shenyang 110035,China)

【机构】 沈阳建筑大学市政与环境工程学院沈阳市北部污水处理厂沈阳市北部污水处理厂 辽宁沈阳110168辽宁沈阳110168辽宁沈阳110035

【摘要】 曝气生物滤池在污水深度处理中的挂膜启动中,先用活性污泥闷曝接种,然后通入污水厂初沉池出水,逐步提高进水流速,到滤料表面形成稳定生物膜后改进污水厂二级出水。试验结果表明,挂膜启动中使用污水处理厂初沉池的出水作为原水,挂膜速度快,两周后出水CODCr和NH3-N去除率分别稳定在70%和80%以上。

【Abstract】 The start-up of biological aerated filter has been studied by using the water of primary sedimentation tank effluent as resource water.Firstly,the filter is filled with active sludge and O2 is supplied by the air compressor.Then the water of primary sedimentation tank effluent is fed to the BAFs,to make the influent water flow speed higher gradually,until the media of BAFs have been covered with stable biofilm.At last,the effluent of the wastewater treatment plant are fed to the BAFs.The result of this research shows that,feeding the BAFs with the water of primary sedimentation tank effluent,makes the media combined with biofilm quickly.After two weeks,the removal of CODCr and NH3-N reach 70% and 80% stably.