节点文献

一次人工引发闪电初始电流及其电磁场变化特征

The Current and Electromagnetic Field in the Initial Stage of an Artificially-Triggered Lightning

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨静郄秀书张其林周筠珺冯桂力孔祥贞张廷龙肖庆复张广庶王怀斌

【Author】 YANG Jing1,QIE Xiu-shu2,ZHANG Qi-lin1,ZHOU Yun-jun1,FENG Gui-li1,KONG Xiang-zhen1,ZHANG Ting-long1,XIAO Qing-fu1,ZHANG Guang-shu1,WANG Huai-bin1(1.Cold and Arid Regions Environmental and Engineering Research Institute,Chinese Academy of Sciences,Lanzhou 730000,China;2.Laborator of Middle Atmosphere and Global Environment Observation,Institute of Atmospheric Physics,Chinese Academy of Sciences,Beijing 100029,China)

【机构】 中国科学院寒区旱区环境与工程研究所中国科学院大气物理研究所中层大气与全球环境探测实验室中国科学院寒区旱区环境与工程研究所 甘肃兰州730000北京100029甘肃兰州730000

【摘要】 研制了近距离闪电磁场变化测量系统,并在2005年夏季山东滨州的人工引发闪电试验中,获得了闪电电流和距闪电通道60 m处的1μs时间分辨率的电磁场变化同步观测资料。本文详细分析了一次人工引发闪电放电初始阶段的电流及近距离电磁场。本次引发闪电中火箭拖带的导线底端通过一段5 m左右的尼龙线与引流杆相接,这段空气间隙击穿放电所产生的电流为720A,对应的60 m处电场和磁感应强度变化分别为0.38 kV/m和11.26μT。对同步资料的进一步分析表明,人工引发闪电上行正先导电流脉冲时间间隔为18.0~25.0μs,平均峰值电流为23.0A,变化范围为16.9~41.0A;单个先导过程转移电荷量的平均值为84.3μC,变化范围为57.8~141.0μC。60 m处先导电场峰值和磁感应强度峰值的平均值分别为16.7 V/m和0.3μT,变化范围分别为8.7~28.2V/m和0.116~0.544μT。先导电流峰值Ip(A)与其产生的磁感应强度峰值B(μT)之间满足Ip=61.9B+2.56。

【Abstract】 A magnetic field measuring system of close lightning was developed.Synchronous data of the current and close electromagnetic field of the triggered lightning with 1 μs time resolution have been obtained in Binzhou,Shandong Province during the summer of 2005.the characteristics of the current and close electromagnetic field in the initial stage(IS) of a triggered lightning are examined in detail.The triggering technique was a kind of classical one,but with an about 5 m Nilong at the bottom of the wire.The results show that the current of the discharge between the lower end of the wire and the lightning rod is about 720A.The corresponding electric and magnetic field of the first stroke at 60 m is 0.38 kV·m-1 and 11.26 μT,respectively.Further analysis show that the time interval between adjacent pulses in the stage of upward positive leader(UPL) varying from a minimum of 18.0 μs to a maximum of 25.0 μs.The geometric mean(GM) of the UPL peak current and charge transferred is 23.0A and 84.3 C with the ranges of 16.9~41.0A and 57.8~141.0 μC,respectively.At a distance of 60 m from the lightning channel the electric field of the UPL varies from 8.7 V·m-1 to 28.2 V·m-1 with a GM of 16.7 V·m-1 and magnetic field from 0.116 T to 0.544 μT with a GM of 0.3 μT.The relationship between peak current Ip(A) of the UPL and of the associated peak magnetic electric field B(μT) at 60 m can be fitted as Ip=61.9B+2.56.

【关键词】 引发闪电先导电流电磁场
【Key words】 Triggered lightningLeaderCurrentElectromagnetic field
【基金】 国家杰出青年科学基金项目(40325013);国家自然科学基金项目(40675008)共同资助
  • 【文献出处】 高原气象 ,Plateau Meteorology , 编辑部邮箱 ,2007年03期
  • 【分类号】P427.3
  • 【被引频次】5
  • 【下载频次】293
节点文献中: 

本文链接的文献网络图示:

本文的引文网络