节点文献
地铁车站屏蔽门渗漏风量数值分析
Rate of Station Screen Door Leakage Air Flow
【摘要】 结合广州地铁隧道通风系统优化方案及站台设置屏蔽门后的实际情况,利用CFD计算模型分析了车站隧道采用典型气流组织方式下屏蔽门开启时的渗漏风量。分析了渗漏风量对车站公共区通风空调系统的影响,重新认识了地铁车站设置屏蔽门后地铁车站公共区的空调冷负荷。
【Abstract】 Based on the optimized tunnel ventilation system and the condition when platform screen door of Guangzhou metro are installed,this paper establishes CFD model and analyses the leakage air flow rate of the typical air organizing mode when platform screen door opens, and the influence to the cooling-load of the station public area, this paper holds that the cooling-load of metro public area when the platform screen doors a installed shall be re-evaluated.
【关键词】 地铁车站;
站台屏蔽门;
空调;
渗漏风量;
【Key words】 metro station; platform screen door; air conditioning; leakage air flow rate;
【Key words】 metro station; platform screen door; air conditioning; leakage air flow rate;
- 【文献出处】 城市轨道交通研究 ,Urban Mass Transit , 编辑部邮箱 ,2007年01期
- 【分类号】U231.5
- 【被引频次】31