节点文献

眼底图像形态参数测定

Automated measurement of retinal image parameters of shape

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 曾碧新谢忠好

【Author】 ZENG Bi-xin,XIE Zhong-hao.Department of Biology & Medical Engineering,Wenzhou Medical College,Wenzhou China,325027

【机构】 温州医学院生物医学工程系温州医学院生物医学工程系 浙江温州325027浙江温州325027

【摘要】 目的介绍一种能与传统的眼底照相机匹配的眼底图像处理系统的图像形态参数测定方法。方法设计针对眼底视网膜图像形态参数进行自动测量的方法,并用VC++程序实现。结果与结论该系统不仅能测量眼底视网膜图像的视杯、视盘的面积、周长、横径、纵径及纵横径比等参数,同时还能测量眼底血管的线径及角度等形态参数。

【Abstract】 Objective To introduce a system for measuring retinal image parameters of shape.Methods To design an algorithm for automatically measuring retinal image shape parameters and to project the results on a computer monitor using the VC++ program.Results and Conclusion This system could measure the length between any two points in the image and the area,perimeter,transverse and vertical diameters of the optic cup or optic disk.It could also provide the ratio of the area of the optic cup to that of the optic disk and the ratio of the transverse diameter to the vertical diameter of the optic cup or optic disk.

  • 【文献出处】 眼视光学杂志 ,Chinese Journal of Optometry & Ophthalmology , 编辑部邮箱 ,2006年03期
  • 【分类号】R770.43
  • 【被引频次】1
  • 【下载频次】118
节点文献中: 

本文链接的文献网络图示:

本文的引文网络