R290与R404A在水平管内沸腾换热的压降研究
In-tube Evaporation Pressure-drop Characteristics of R290 and R404A
【摘要】 将R22的两种新型替代工质R290和R404A在光管和内螺纹管中的沸腾换热压降实验结果与Lockhart&Martinelli压降计算关联式预测结果进行了比较,并依据工质R290和R404A在内螺纹管中的实验压降值对Lockhart&Martinelli压降计算关联式进行了修正。结果表明Lockhart&Martinelli关联式对R404A在光管和内螺纹管的沸腾换热摩擦压降,均有良好的预测精度,平均偏差分别为-11.52%和-17.86%。Lockhart&Martinelli关联式可以较好的预测R290在光管内的沸腾换热摩擦压降,平均偏差为-21.68%;经修正后的Lockhart&Martinelli关联式可以较好的预测R290在在内螺纹管中的沸腾换热摩擦压降,Lockhart&Martinelli关联式乘上修正系数2.06后的修正值与实验值偏差较小,平均偏差为2.37%。研究结果对R290和R404A蒸发器的工程设计及优化具有一定参考意义。
【Abstract】 The experimental results of in-tube evaporation pressure-drop of R290 and R404A in the horizontal smooth tube and the horizontal microfin tube were compared with calculation results by Lockhart & Martinelli pressure-drop correlation,respectively.Moreover,based on the experimental data of R290 and R404A,Lockhart & Martinelli pressure-drop correlation was modified adequately.For R404A.the correlation shows good agreement with experimental values with mean deviation of-11.52% for the smooth tube and-17.86% for the microfin tube.Lockhart & Martinelli pressure drop correlation can also predict well the in-tube evaporation pressure-drop of R290 for the smooth tube with mean deviation of-21.68%.However,2.06 to agree well with the experimented data should multiply the predicted value for the microfin tube by Lockhart & Martinelli correlation,and the mean deviation is 2.37%.
【Key words】 Engineering thermalphysics; R290; R404A; In-tube evaporation pressure-drop; Correlation;
- 【文献出处】 制冷学报 ,Journal of Refrigeration , 编辑部邮箱 ,2006年02期
- 【分类号】TB611
- 【被引频次】27