实时三维超声估测心室搏出量的实验研究

Quantify ventricular stroke volume in vivo using real-time three-dimensional echocardiography

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈国珍梁雪村黄国英张陈

【Author】 CHEN Guo-zhen,LIANG Xue-cun,HUANG Guo-ying,ZHANG Chen.Pediatric Heart Center,Children’s Hospital of Fudan University,Shanghai 200032,China

【机构】 复旦大学附属儿科医院心血管中心复旦大学附属儿科医院心血管中心

【摘要】 目的评价实时三维超声心动图(RT-3DE)估测心室搏出量的可行性和准确性。方法以Swan-Ganz导管热稀释法测定的心室搏出量为标准,应用Philips RT-3DE系统采集10头健康猪心“金字塔形”数据库,结合TomTec4D Cardio-View RT测量软件用心尖长轴8平面法测量左、右室舒张末期和收缩末期容量,计算左、右室搏出量,并与二维超声双平面Si mpson法测值比较。结果所有猪心均获满意的左、右室RT-3DE显示,其形态与直视下猪心心室实际形态相似。其中,RT-3DE8平面法估测左室搏出量[(24.58±3.44)ml]与其右室搏出量[(23.58±3.18)ml]呈高度相关(r=0.93),并与Swan-Ganz导管热稀释法测值[(25.64±3.18)ml]有良好相关性(r=0.85,r=0.92)。经方差分析、SNK均数间两两比较检验,三者间差异无统计学意义(P>0.05)。而二维超声双平面Si mpson法估测左室搏出量[(16.83±4.71)ml]与其右室搏出量[(10.10±2.87)ml]与Swan-Ganz导管热稀释法测值仅呈低度相关(r=0.59,r=0.39),尤以右室搏出量低估程度较明显,且其左、右室搏出量间相关性较低(r=0.76)。经方差分析、SNK检验,三者间差异有统计学意义(P<0.05)。结论RT-3DE是估测心室搏出量的可靠手段。

【Abstract】 Objective To evaluate the feasibility and accuracy of real-time three-dimensional echocardiography (RT-3DE) in quantifying ventricular stroke volume in an in vivo experimental study.Methods Ten porcine hearts were examined by RT-3DE and conventional two-dimensional echocardiography (2DE) with Philips Sonos 7500 ultrasound system.The left and right ventricular stoke volume examined by RT-3DE was outlined and calculated by 8-plane method with the 4D Cardio-View RT of TomTec image system,and the results were compared with those of 2DE biplane Simpson-method.The values of ventricular stroke volume measured by Swan-Ganz pulmonary thermodilution method were served as reference values.Results “Full volume” imaging in all porcine hearts was well displayed by RT-3DE.The ventricular shapes displayed by RT-3DE were similar to the anatomic ventricular shapes.From the findings of analysis of variance and Student-Newman-Keuls test,there was no significant difference (P> 0.05 ) between the left ventricular stroke volume with RT-3DE ( 24.58 ± 3.44 )ml,the right ventricular stroke volume with RT-3DE ( 23.58 ± 3.18 )ml and those values measured with Swan-Ganz pulmonary thermodilution method ( 25.64 ± 3.18 )ml.Furthermore,there was well correlation between the left ventricular stroke volume and the right ventricular stroke volume with RT-3DE (r= 0.93 ).They were also well correlated with those values with Swan-Ganz pulmonary thermodilution method (r= 0.85 ,r= 0.92 ).However,there was significant difference (P< 0.05 ) between the left ventricular stroke volume with 2DE ( 16.83 ± 4.71 )ml,the right ventricular stroke volume with 2DE ( 10.10 ± 2.87 )ml and those values with Swan-Ganz pulmonary thermodilution method.Moreover,the right ventricular stroke volume with 2DE was underestimated more than the left ventricular stroke volume with 2DE.There was poor correlation between them (r= 0.76 ).They were also poorly correlated with those values measured with Swan-Ganz pulmonary thermodilution method (r= 0.59 ,r= 0.39 ).Conclusions RT-3DE is a valuable and accurate technique to quantify ventricular stroke volume.

【基金】 中国博士后科学基金资助(2004036113)
  • 【文献出处】 中华超声影像学杂志 ,Chinese Journal of Ultrasonography , 编辑部邮箱 ,2006年06期
  • 【分类号】R445.1
  • 【被引频次】14
  • 【下载频次】84
节点文献中: 

本文链接的文献网络图示:

本文的引文网络