节点文献
环境水样中痕量铀、钚的ICP-MS测定技术研究
Study on the ICP-MS Technology of Trace Uranium and Plutonium in Environmental Water(In Chinese)
【摘要】 建立了环境水中铀、钚的ICP-MS测量方法。分别采集河水、水库水、自来水三种水样各100 L以分析239Pu含量。分析流程为共沉淀—阴离子交换分离纯化—ICP-MS测量,仪器检出限为0.06 ng.L-1。通过标准拟合曲线,用内标法定量,结果表明,河水和自来水中的钚含量低于检出限,水库水中钚的含量为10~14 g/L。将三种水样直接过滤后用ICP-MS测量铀含量,测量结果为0.5~1μg/L。
【Abstract】 The method of detecting U and 239Pu of the water in the environment was founded.100 L water of river,reservoir and tap water were respectively sampled.The concentration of 239Pu was analyzed by ICP-MS after the treatment by coprecipitation-anion exchange,the detection limit was 0.06 ng/L.Standard fitting curve and internal standard method was used to quantity,the result showed that the concentration of 239Pu of the water of river,tap water was (below) the detection limit,the concentration of the water of reservoir was 1014 g/L;All of the water were directly filtrated then detected by ICP-MS,the concentration of U of all the water was 0.5~1 μg/L.
- 【文献出处】 中国核科技报告 ,China Nuclear Science and Technology Report , 编辑部邮箱 ,2006年01期
- 【分类号】X824
- 【被引频次】1
- 【下载频次】349