空气消毒洁净器在医院应用中存在问题的调查

SURVEY OF PROBLEMS IN HOSPITAL USE OF AIR DISINFECTION-CLEANING DEVICES

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 乔宏李凤玲王云波贺玉珍杨月英

【Author】 QIAO Hong,LI Feng-ling,WANG Yun-bo~1,HE Yu-zhen~2,YANG Yue-ying~2(Beijing Municipal Center for Disease Prevention and Control,Beijing 100013;1 East District Center for Disease Prevention and Control,Beijing; 2 Shijingshan District Center for Disease Prevention and Control,Beijing,China)

【机构】 北京市疾病预防控制中心北京市东城区疾病预防控制中心北京市石景山区疾病预防控制中心北京市石景山区疾病预防控制中心 北京100013北京100013

【摘要】 为了解北京市医院空气消毒洁净器应用中的问题,采用现场抽样和空气采样检测方法进行了调查。结果,所调查的空气消毒洁净器中,适用面积符合卫生许可批件和说明书要求的只有32%。有16%的空气消毒器说明书未提供规定使用面积,有32%的医院未提供卫生许可批件。有80%的空气消毒洁净器应用于医院Ⅱ类环境,在有人员活动情况下动态空气消毒的环境内,消毒合格率为42.10%;其余均为III类环境中消毒器在空气静态条件下,消毒合格率均为100%。结论,医院现使用的空气消毒洁净器存在使用不合理现象,用于II类环境动态消毒合格率较低。

【Abstract】 In order to know the problems in use of air disinfection-cleaning devices in hospitals of Beijing,field sampling and air sampling examination method were used to carry out a survey.Results: Of the air disinfection-cleaning devices investigated,only 32% fulfilled the requirement of suitable area specified in sanitary licence and description.The descriptions of 16% of the air disinfectors did not specify the applicable area and 32% of the hospitals could not provide the approval document of sanitary licence.80% of the air disinfection-cleaning devices were used in class-Ⅱenvironment of the hospital and under condition of presence of human activities,the eligible disinfection rate was 42.10% in environment of dynamic air disinfection.The other devices were used under air stationary condition in class-III environment,and the eligible disinfection rate was 100%.Conclusions: There was irrational use of air disinfection-cleaning devices in hospitals and the eligible rate of use in dynamic disinfection in class-Ⅱenvironment was low.

  • 【文献出处】 中国消毒学杂志 ,Chinese Journal of Disinfection , 编辑部邮箱 ,2006年03期