节点文献

转炉冷却烟道泄漏故障分析

Analysis of Leakage Failure of Converter Cooling Air Flue

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 黄文豪; 王军; 杜一庆;

【Author】 HUANG Wen-hao1,WANG Jun1,DU Yi-qing2(1.No.3 Steel Works,Wuhan Iron and Steel Co.,Ltd.,Wuhan,Hubei 430083,China;2.College of Energy and Power Engineering,Huazhong University of Science and Technology,Wuhan,Hubei 430074,China)

【机构】 武汉钢铁有限公司第三炼钢厂; 华中科技大学能源与动力工程学院 湖北武汉430083; 湖北武汉430083; 湖北武汉430074;

【摘要】 针对武钢三炼钢厂的转炉烟气冷却系统汽化器的漏水故障,对系统实际运行参数进行了实测,并根据测得的数据进行高精度热力校核计算。基于校核结果的进一步分析和测试表明,腐蚀疲劳是汽化器漏水故障的主要原因。

【Abstract】 In the light of leakage failure of evaporator in the converter cooling system of No.3 Steel Works,Wuhan Iron and Steel Co.,Ltd.,the operation parameters of the system were measured actually.According to the measurements,a high precise thermal checking calculation was carried out.Further analysis based on the checking calculation and tests proved that corrosion fatigue is the main reason that causes leakage in the air flue.

【关键词】 转炉; 烟气冷却; 泄漏; 腐蚀疲劳;
【Key words】 converter; gas cooling; leakage; corrosion fatigue;
  • 【文献出处】 冶金动力 ,Metallurgical Power , 编辑部邮箱 ,2006年03期
  • 【分类号】TF748.2
  • 【下载频次】84
节点文献中: 

本文链接的文献网络图示:

本文的引文网络