节点文献

纺织品中可萃取痕量汞的测定

Determination of trace extractable mercury in textiles

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 鲁丹阮毅

【Author】 LU Dan,RUAN Yi(Technic Centre of Zhejiang Entry-Exit Inspection & Quarantine Bureau,Hangzhou 310012,China)

【机构】 浙江出入境检验检疫局技术中心浙江出入境检验检疫局技术中心 浙江杭州310012浙江杭州310012

【摘要】 建立采用氢化物发生电感耦合等离子发射光谱(HG-ICP-AES),测定纺织品中可萃取痕量汞的方法。通过对ICP-AES工作参数进行优化和选择,方法的检出限为0.11μg/L,最小检出量为0.002 2 mg/kg;汞含量为20.0μg/L时,相对标准偏差为4.9%;汞含量为5.5μg/L时,相对标准偏差为6.3%(n=8);回收率为93.3%~102.7%。该方法可满足Oeko-Tex标准100对纺织品中可萃取痕量汞的检测要求。

【Abstract】 A method for the determination of trace extractable mercury in textiles by HG-ICP-AES has been developed.Operation parameters of ICP-AES were optimized and selected.The detection limit was 0.11μg/L.The minimum detection quantity was 0.0022 mg/kg.The RSD was 4.9% at a level of 20.0μg/L and 6.3% for 5.5μg/L(n=8).The recovery was in the range of 93.3%~102.7%.This method is applicable to the determination of trace extractable mercury in textiles with Oeko-Tex Standard 100.

【关键词】 测试纺织品
【Key words】 testingmercurytextiles
  • 【分类号】TS107
  • 【被引频次】2
  • 【下载频次】70