节点文献
PESA测量中单个标准样品刻度方法适用范围研究
The study of the single standard sample calibration method in the roton elastic scattering analysis(PESA)
【摘要】 用3.5μm厚Mylar膜作为标准样品,对1.4~2.5MeV范围不同能量下PESA测量刻度系数进行测量。结果在此能量范围内不同能量下平均刻度系数差别小于10%。用2.5MeV质子束,对单层,双层和三层3.5μm厚Mylar分别进行PESA测量,它们平均刻度系数相差在3%以内。结果表明:对厚度小于9mg/cm2气溶胶样品或2.5MeV质子穿透过程中能量损失小于1.1MeV其他样品,2.5MeVPESA测量是可以用单标准样品进行刻度。
【Abstract】 Proton Elastic Scattering Analysis(PESA) facilities with proton energy from 1.4~2.5MeV were calibrated used 3.5μm Mylar film,and it was shown that the difference of the calibrate coefficients in different energy is less than 10%. Single,double and triple layers of 3.5μm Mylar film were used to calibrate the 2.5MeV PESA method,their calibrate coefficients differ within 3%.These results indicate that the 2.5MeV PESA method which calibrated by single standard sample is valid for measuring of H content of aerosol samples accompanied with PIXE analysis,and it’s also valid for analysis of any other samples through which the energy loss of 2.5MeV proton is less than 1.1MeV.
【Key words】 Proton elastic scattering analysis Standard sample Calibration Mylar film Hydrogen content;
- 【文献出处】 现代仪器 ,Modern Instruments , 编辑部邮箱 ,2006年01期
- 【分类号】X831
- 【被引频次】4
- 【下载频次】31