固溶温度对超级双相不锈钢00Cr25Ni7Mo4N组织和性能的影响
Influence of Solution Temperature on Structure and Properties of Super Duplex Stainless Steel 00Cr25Ni7Mo4N
【摘要】 试验和测试了900-1 300℃固溶处理时双相不锈钢00Cr25Ni7Mo4N的相组成、冲击能AKV和硬度(HRC)值。试验结果表明,在900-1 020℃固溶处理时,双相不锈钢中有16.97%-3.22%σ相析出,使钢的冲击能AKV值从1 040-1 250℃处理的224~280 J降至3~44 J。该双相不锈钢的热加工温度应大于1 040℃,其最佳固溶处理温度为1 040~1 100℃。
【Abstract】 The phase composition, impact energy AKV and hardness HRC value of duplex stainless steel 00Cr25Ni7Mo4N solution treated at 900-1 300℃have been studied and examined. The results showed that 16.97% -3.22%σ- phase precipitated in duplex stainless steel during solution treatment at 900-1 020℃led to the impact energy AKV value of steel decreasing to 3 - 44 J from 224 - 280 J while steel treated at 1 040-1 250℃. The hot work temperature of the duplex stainless steel should be higher than 1 040℃and its optimum solution treatment temperature is 1 040-1 100℃.
【Key words】 Super Duplex Stainless Steel 00Cr25Ni7Mo4N; Solution Treatment; σ-Phase; Impact Energy;