节点文献
种植区骨皮质厚度对种植体骨界面应力分布的影响
Experimental Research On the Stress Distributions in the Implant-Bone Interface Related to Cortical Thickness around Implant
【摘要】 目的研究种植区骨皮质厚度对种植体骨界面应力分布的影响。方法建立含种植体的颌骨三维有限元模型,应用三维有限元法,研究在不同厚度的骨皮质支持下,种植区骨皮质厚度对种植体骨界面应力分布的规律。结果骨皮质厚度对种植体颈部皮质骨内的应力有较大的影响,两者呈负相关。随着骨皮质厚度的增加,种植体骨界面骨皮质内的应力逐步减小。骨皮质厚度<2 mm时种植体界面骨皮质颈部的应力值明显高于骨皮质厚度≥2mm时的应力值(P<0.05);当骨皮质厚度≥2 mm时,随着骨皮质厚度的增加,种植体界面皮质骨内的应力值虽然逐步减小,但是其变化并无显著性差异。结论种植区骨皮质厚度至少应≥2 mm,以保证其生物力学的相容性。
【Abstract】 Objective To investigate the stress distributions in the implant-bone interface related to cortical thickness around implant.Methods First,construct the three-dimensional finite element models of edentulous mandible with different thickness of cortical bone and the stress distributions in the implant-bone interface were investigated under both axial and oblique loading.Results The results of this study indicated that the relationship between the cortical thickness of mandible and stress distribution in implant-bone interface was negative,the greater thickness of cortical bone,the less was the stress concentration.And the thickness of cortical bone around implant should be at least 2 mm,or the stess of implant-bone interface may increase significantly(P<0.05).Conclusion In order to obtain the long-term success of implant-prosthesis,the thickness of cortical bone around implants should be at least 2 mm.
【Key words】 implant; three-dimensional finite element models; thickness of cortical bone; stress distribution;
- 【文献出处】 同济大学学报(医学版) ,Journal of Tongji University(Medical Science) , 编辑部邮箱 ,2006年01期
- 【分类号】R783.6
- 【被引频次】41
- 【下载频次】277