节点文献
2000t/d带Pyroclon预分解窑窑尾高温风机的工程诊断
Diagnosis of kiln induce fan of a Proclon precalciner
【摘要】 针对福建SD公司2000t/d生产线投产以来产量未能达标的原因,重点对窑尾高温风机进行了检测和诊断,做出了全面客观的评价,得到了该风机及其配套电动机实际工作性能与原设计性能相符的结论,而未能达标的主要原因是工作电压太低,制约了电动机和风机能力的发挥。
【Abstract】 Fujian SD cement production line with a capacity of 2 000t/d hadn’t attained the designed standard since used. The thermal engineering examinations to the high temperature fan of kiln was diagnosed,and some general and objective evaluate was made out,and a conclusion was drawn that the fan and its motor system was reasonable but its working voltage was deficient.
- 【文献出处】 水泥 ,Cement , 编辑部邮箱 ,2006年08期
- 【分类号】TQ172.622.26
- 【被引频次】1
- 【下载频次】67