电梯层门电气联锁的检验要求及方法
Inspection Requirement and Method on Electric Interlocking of Elevator Gate Door
【摘要】 层门门锁是电梯安全检验中的重中之重,根据GB7588-2003的要求,国家质量监督检验检疫总局制定了《电梯监督检验规程》。电梯检验员的检验要求和方法及门锁不合格会造成的种种危害作一一论述。
【Abstract】 Elevator gate door electric interlock is a very important item in elevator security inspection. On the basis of GB7588-2003, General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China established the elevator regulation of supervision and inspection. This article discussed all kinds of harm about inspector’s inspection request, method and unqualified interlock.
【关键词】 电梯;
层门电气联锁;
检验要求;
安全触点;
【Key words】 Elevator; Gate door electric interlock; Inspection request; Security contact;
【Key words】 Elevator; Gate door electric interlock; Inspection request; Security contact;
- 【文献出处】 现代制造技术与装备 ,Modern Manufacturing Technology and Equipment , 编辑部邮箱 ,2006年04期
- 【分类号】TU976.3
- 【被引频次】7
- 【下载频次】147