节点文献

黄岛电厂K-225-130-Ⅰ型机组高加入口三通阀改造

Retrofit of Three-way Valve at the Inlet of High Pressure Heater Huangdao Power Plant

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【摘要】 我厂二期两台前苏联机组配套的F763Y-25 DN300型水压保护三通阀经常出现卡涩和存在小旁路不严现象,影响高加投入率和给水温度,我们在机组小修中对其进行了改造,解决了高加保护不能可靠投入问题,提高了高加运行的安全可靠性,效果较好,在同类型机组中具有较高的推广应用价值。

【Abstract】 Model F763Y-25 DN300 water pressure protection three-way valve for the two former USSR units in the second phase of our plant often became blocked and small bypass was not tight, which influenced service rate of high pressure heater and feed temperature, we had retrofitted it during minor overhaul of the units, solved unreliable operation of high pressure heater protection and increased operation safety and reliability of high pressure heater, the effect is relatively good, it has high promotional application value in similar units.

  • 【文献出处】 山东电力技术 ,Shandong Electric Power , 编辑部邮箱 ,2006年01期
  • 【分类号】TK263
  • 【被引频次】3
  • 【下载频次】43
节点文献中: 

本文链接的文献网络图示:

本文的引文网络