节点文献

DSCM中摄像机光轴与物面不垂直引起的误差分析

Errors caused by misalignment of the optical camera axis and the object surface in the DSCM

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 孟利波; 金观昌; 姚学锋;

【Author】 MENG Libo,JIN Guanchang,YAO Xuefeng(Department of Engineering Mechanics,Tsinghua University,Beijing 100084,China)

【机构】 清华大学工程力学系; 清华大学工程力学系 北京100084; 北京100084;

【摘要】 该文研究了数字散斑相关方法(DSCM)中由于摄像机与被测物面不垂直而引起的误差。首先从成像原理上进行分析,得出当位移和偏差角度比较小时,误差分别与它们成线性关系。为验证这一结论,提出了引入摄像机成像模型的数字模拟散斑图像生成方法;采用数字散斑相关方法,对模拟散斑图像进行计算,计算的结果与理论分析的误差公式结果非常吻合。基于数字散斑相关测量灵敏度为0.01像素,要求不垂直度或被测平面的平面度应小于5,°这也是二维数字散斑可否用于曲面测量的判据。

【Abstract】 The errors in the digital speckle correlation method(DSCM) caused by misalignment of the optical camera axis relative to the object plane were analyzed theoretically to show that the errors are linearly related to the displacement and non-perpendicularity when these two items are small.The results were verified using an improved speckle pattern generation simulation with a 3-D camera model.For a DSCM measuring sensitivity of 0.01 pixels,the misalignment from perpendicular of the camera axis or the curvature of the measuring plane must be less than 5°.The method also provides a criterion for curve plane measurement using 2-D DSCM.

  • 【文献出处】 清华大学学报(自然科学版) ,Journal of Tsinghua University(Science and Technology) , 编辑部邮箱 ,2006年11期
  • 【分类号】O348
  • 【被引频次】95
  • 【下载频次】560
节点文献中: 

本文链接的文献网络图示:

本文的引文网络