节点文献

强对流气体保护退火炉热平衡计算

Heating Balance Calculation of Strong Convection Gas Shield Annealing Furnace

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 徐效谦

【Author】 Xu Xiaoqian (Dalian Steel Wire Products Co.of Dongbei Special Steel Group 116031)

【机构】 东北特殊钢集团大连钢丝制品公司 116031

【摘要】 说明钢丝加热、炉体表面散热和电功率计算公式。以具体实例计算出装炉量为8~15 t,最高使用温度为900℃的退火炉在考虑装料炉架、炉盖、内胆、保护气体和冷却水消耗情况下的加热功率为280 kW,并以此为基础,推算出不同退火温度和不同装炉量时的加热时间,为制定退火工艺提供依据。

【Abstract】 To explain calculation formula of steel wire heating,furnace surface heat dispersion and electric power.Heating power calculated by example is 280kW when furnace capacity is 8~15t and the most highest using temperature of annealing furnace is 900℃ and furnace frame,furnace cover,inner sleeve,consumption of shield gas and cooling water are considered.On the basis of it,heating time is calculated on the condition of different annealing temperature and furnace capacity and it can provide foundation for making annealing process.

【关键词】 退火炉热平衡加热功率
【Key words】 annealing furnaceheating balanceheating power
  • 【文献出处】 金属制品 ,Steel Wire Products , 编辑部邮箱 ,2006年05期
  • 【分类号】TG155.1
  • 【被引频次】2
  • 【下载频次】110
节点文献中: 

本文链接的文献网络图示:

本文的引文网络