节点文献

精密光束偏离装置棱镜组件的光机热分析

Optical-mechanical-thermal Analysis on Prism Assembly of Precision Light Beam Scanner

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李安虎孙建锋朱勇建徐荣伟刘立人

【Author】 Li Anhu~ 1,2 ,Sun Jianfeng~1,Zhu Yongjian~ 1,2 ,Xu Rongwei~ 1,2 ,Liu Liren~1 1 Shanghai Institute of Optics and Fine Mechanics, the Chinese Academy of Sciences, Shanghai 2018002 Graduate School, of the Chinese Academy of Sciences, Beijing 100039

【机构】 中国科学院上海光学精密机械研究所中国科学院上海光学精密机械研究所 上海201800中国科学院研究生院北京100049上海201800

【摘要】 以精密光束偏离装置的棱镜组件为有限元模型,进行了光机热集成分析·对棱镜组件的结构强度进行了校核,分析了机械载荷作用下的镜面变形;通过模态分析,给出了装置的动态特性和镜面面形振动幅值的变化情况;最后对棱镜的热弹性变形进行了分析,对棱镜的光学性能进行了评价·结果表明:棱镜组件的最大变形在10nm量级,最大应力为0.403MPa,应力和应变相对于结构的准确度要求和材料的许用应力具有较大的裕度;前后棱镜组件的固有频率都大于550Hz,装置具有良好的动态性能;通过对比棱镜在热-结构耦合分析和机械载荷下的分析结果,说明热效应对棱镜表面变形的影响远远大于机械载荷的影响·装置使用时必须采取严格的温控措施·

【Abstract】 Regarding the prism assembly of precision light beam scanner as a finite element model, the optical-mechanical-thermal integrating analysis was done. In terms of structure statics, the structure design and intensity of the prism assemble was verified and checked, and the surface deformation analysis of the prism was correspondingly provided under steady-state mechanical loading; Through the mode analysis , the dynamic characteristic of the device and the vibration amplitude change of the prism surface was obtained; then the hot elasticity distortion of the prism was analyzed and the estimation of optics performance of the prism was given. The analysis results show: the maximal distortion of the prism assembly was 10 nm magnitude and the maximal stress was 0.403 MPa, which has much tolerance to the admissible stress of material and the precision requirement of structure; The natural frequency of the front prism assembly and the back one both were greater than 550 Hz, which indicated the dynamic performance of the device very well.Through comparing thermal-structure coupling analysis with mechanical loading analysis, the influence of heat effect on the prism surface deformations was proved far greater than the influence of mechanical loading, so the strict temperature-controlled measure must be taken when the device is used.

【基金】 上海市科学技术发展基金(046105004);中国科学院创新计划资助项目
  • 【文献出处】 光子学报 ,Acta Photonica Sinica , 编辑部邮箱 ,2006年07期
  • 【分类号】TH74
  • 【被引频次】5
  • 【下载频次】211
节点文献中: 

本文链接的文献网络图示:

本文的引文网络