节点文献

象限探测器非均匀性的影响分析及软校正算法

Analysis of the Non-uniformity Effect and Soft Correction Algorithm for Four-quadrant Detector

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 党丽萍刘君华唐树刚

【Author】 Dang Liping 1,2,Liu Junhua1,Tang Shuguang3 1 School Of Electric Engineering, Xi′an Jiaotong University,Xi′an 710049 2 Army Representation Office Be Stationed In Xiguang Group, Xi′an 710043 3 Xi′an Institute of Surveying and Mappig ,Xi′an 710063

【机构】 西安交通大学电气工程学院驻西光集团军代室 西安710043总参西安测绘研究所西安710049西安710063

【摘要】 定量分析了四象限探测器用于目标跟踪时,其光电响应不均匀性对输出特性线性度及跟踪定位准确度的影响,给出了不均匀性校正的下限·提出了一种综合补偿光分布、探测器暗电流、通道增益的多元软校正方法·该方法将非线性误差控制在5%,跟踪定位准确度2%·与补偿增益的硬件校正和不消除暗电流的软校正方法相比,非线性误差减小2%,定位准确度提高了近3%·

【Abstract】 The non-uniformity effect of the four-quadrant detector on the output signal linearity and accuracy of trace were analyzed and position locating when the detector was used in the target trace, and the bottom limit to the non-uniformity was also given. Based on this, a multi-correction method, which used comprehensive compensation intensity distribution, dead current, and channel of amplifier coefficient was presented for the first time. By using this method, the non-linear error was limited to 5% and the accuracy of trace and position locating was 2%. Compared with the methods using the hardware correction of compensation channel of amplifier coefficient and the soft correction with dead current retained, the non-linear error was reduced to 2% and the accuracy of position locating was improved nearly 3% by the multi-correction method.

【基金】 国家自然科学基金(60276037);国防技术基础研究(ZLBOS145)资助
  • 【文献出处】 光子学报 ,Acta Photonica Sinica , 编辑部邮箱 ,2006年04期
  • 【分类号】TN36
  • 【被引频次】21
  • 【下载频次】278
节点文献中: 

本文链接的文献网络图示:

本文的引文网络