节点文献
深度处理污染河水的反渗透膜污染特性与防治
Fouling Characteristics and Prevention of RO Membrane for Advanced Treatment of Polluted River Water
【摘要】 对以受污染河水为原水的反渗透系统膜污染问题进行了分析,初步认定反渗透膜污染是以生物粘泥、铁的氧化物及有机物为主的综合污染,而预处理的不完善、清洗方案选择不合理以及杀菌措施不够是导致膜污染的主要原因,最后提出了相应的解决办法。
【Abstract】 The membrane fouling of reverse osmosis system for treatment of polluted river water was analyzed. The membrane fouling is considered mainly caused by biological slime, iron oxide and organics, which is a synthesis fouling. The fouling reasons are the deficient pretreatment, the unreasonable choice of cleaning methods as well as the inadequate disinfection. In the end, the solving methods to the membrane fouling are proposed.
【关键词】 污染河水;
预处理;
反渗透;
膜污染;
【Key words】 polluted river water; pretreatment; reverse osmosis; membrane fouling;
【Key words】 polluted river water; pretreatment; reverse osmosis; membrane fouling;
【基金】 2005年河北省教育厅资助项目(2005110)
- 【文献出处】 中国给水排水 ,China Water & Wastewater , 编辑部邮箱 ,2006年20期
- 【分类号】TU991.2
- 【被引频次】7
- 【下载频次】241