节点文献

血管内支架置入术治疗Stanford B型主动脉夹层

Endovascular Aortic Stent-graft Placement for Treatment of Stanford Type B Aortic Dissection:Experience of 15 Cases

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 赵金平廖永德高思海马业新胡道予

【Author】 ZHAO Jin-ping,LIAO Yong-de,GAO Si-hai,et al.Department of Cardiothoracic Surgery,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,P.R.China

【机构】 华中科技大学同济医学院附属同济医院胸心外科华中科技大学同济医学院附属同济医院胸心外科华中科技大学同济医学院附属同济医院胸心血管内科华中科技大学同济医学院附属同济医院放射科

【摘要】 目的:总结主动脉血管支架置入术治疗StanfordB型主动脉夹层的临床经验。方法:术前对15例StanfordB型主动脉夹层患者进行主动脉全程薄层增强CT扫描及血管成像,以获得主动脉夹层病变解剖学特征。在局麻下行主动脉造影,并与CT结果比较,选取支架血管型号。全麻下切开左股动脉或右股动脉,置入支架血管,封堵原发破口,重复造影检查有无内漏。术后1周及1年行CT随访,观察有无内漏、支架移位和假腔变化。结果:15例均获临床成功。1例见少量近端内漏,未发生其他并发症。CT随访,5例主动脉夹层消失,余者假腔内血栓形成。结论:与传统手术相比,腔内隔绝术治疗StanfordB型主动脉夹层具有创伤小、并发症少、安全性高等优点,近期疗效满意。

【Abstract】 Objective:To introduce the experience of endovascular stent-graft placement for treatment of 15 cases of Stanford type B aortic dissection. Methods:Contrast-enhanced thin-slice CT was performed preoperatively to obtain the anatomical characteristics of the aortic dissection.Aortography was performed under local anesthesia.The size of the endovascular stent-grafts were chosen according to consensus of aortic CT and aortography.Vascular access was obtained through femoral arteriotomy and stent-graft was placed in the true lumen of the aorta to occlude the primary intimal tear under general anesthesia.Immediate aortography was performed after placement of the stent-graft to demonstrate if there existed any endoleak.Follow-up CT angiography 1 week and 1 year postoperatively was used to evaluate treatment efficacy.Results:Clinical success was achieved in all 15 cases.Immediate aortography revealed minor endoleak in one case,no other complications occurred.Follow-up CT showed that the false lumens disappeared in 5 cases and were filled with thrombus in the other patients.Conclusion:The short- and mid-term efficacy of endovascular stent-graft therapy for Stanford type B aortic dissection is satisfactory with less invasiveness and definite safety.

  • 【文献出处】 放射学实践 ,Radiologic Practice , 编辑部邮箱 ,2006年06期
  • 【分类号】R543.1
  • 【被引频次】3
  • 【下载频次】87