节点文献
220t/h锅炉水冷壁腐蚀分析与预防
The Decay Analysis and Prevention about the Water Wall in 220t/h Boiler
【摘要】 针对某热电厂220 t/h锅炉水冷壁高温腐蚀的严重情况,对水冷壁腐蚀产物的显微结构、化学组成及矿物组成进行了系统分析,揭示了水冷壁高温腐蚀的机理,分析了高温腐蚀的原因,并提出了有效的预防措施。
【Abstract】 As for the serious high-temperature corrosion of water wall in power plant,the corrosion product’s structure,chemical composition and mineral composition of cold water wall are analyzed,the corrosion mechanism is revealed,the causes of high-temperature corrosion are analyzed and effective prevention measures are put forward.
- 【文献出处】 电站系统工程 ,Power System Engineering , 编辑部邮箱 ,2006年06期
- 【分类号】TK224.9
- 【被引频次】6