节点文献

微型柱现场在线采样技术测定海水中痕量铜

Determination of trace copper in seawater by minicolumn field sampling technique

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 吴冬梅王爱霞郭黎平

【Author】 WU dong-mei,WANG Ai-xia,GUO LI-ping(Faculty of Chemistry,Northeast Normal University,Changchun 130024,China)

【机构】 东北师范大学化学学院东北师范大学化学学院 吉林长春130024吉林长春130024

【摘要】 在海水(pH7.8~8.5)条件下,使用微型柱现场在线采样(MFS)技术直接对海水中痕量铜进行预富集,然后在实验室中采用流动注射-火焰原子吸收(FI-FAAS)联用系统成功地实现了对海水中铜的测定.当采样体积为50 mL时,其富集因子为432,检出限为0.019μg/L,相对标准偏差为1.68%.对海水中微量元素标准物质GBW(E)080040和大连老虎滩区域海水中的Cu进行分析,均得到满意结果.

【Abstract】 Cu in seawater samples were collected and pre-concentrated in site by on-line minicolumn field sampling(MFS) technique under the acidity of seawater,the adsorption materials of the column used for the first was Amberlite XAD-2 functionalized with dithizone(H2DZ)copolymer resin(XAD-H2DZ).Then in the laboratory,these minicolumns were determined by flow injectionflame atomic absorption spectrometry(FI-FAAS).The enrichment factor of 432 was obtained for 50 mL of sampling volumes,and the detection limit was 0.019 μg/L and relative standard deviation(5 μg/L,n=11) was 1.68% at the same conditions.The method was successfully applied to the determination of copper in a certified reference materials(GBW(E)080040) and in seawater samples from Dalian Laohutan,respectively,and the results was satisfactory.

【基金】 国家自然科学基金资助项目(50473032)
  • 【文献出处】 东北师大学报(自然科学版) ,Journal of Northeast Normal University , 编辑部邮箱 ,2006年01期
  • 【分类号】X834
  • 【被引频次】4
  • 【下载频次】115
节点文献中: 

本文链接的文献网络图示:

本文的引文网络