节点文献
透光率脉动检测技术评价混凝剂的混凝效果
Research on Evaluation of Coagulation Effect by the Technique of Fluctuation of Transmitted Light
【摘要】 介绍了一种评价混凝效果的新方法———透光率脉动检测法 ,并以不同浊度的高岭土悬浊液为研究对象 ,投加 3种不同剂量的混凝剂 (硫酸铝、聚合氯化铝、高分子有机絮凝剂HCA) ,通过PDA2 0 0 0检测仪对混凝效果的检测 ,以R指数评价不同混凝剂在多种浊度水样中的混凝效果。结果表明 ,透光率脉动检测技术是一种检测混凝性能的可靠方法
【Abstract】 This paper introduces an evaluation method of coagulation effect, taking kaoline suspend liquid of different turbidity as the research object. Three different dosages of coagulation were casted to the liquid, which includes alum, PACl, HCA, and through the PDA2000.The coagulation effect was detected. The \%R\% index was used to evaluate the coagulation effect of different coagulation in different turbidity water samples. The results showed that the technique of fluctuation of transmitted light was a good method to evaluate coagulate performance.
【Key words】 coagulation effect; water treatment; fluctuation of transmitted light; automatic coagulate dosage;
- 【文献出处】 中山大学学报(自然科学版) ,Acta Scientiarum Naturalium Universitatis Sunyatseni , 编辑部邮箱 ,2002年02期
- 【分类号】TU991
- 【被引频次】5