节点文献
200L桶装α废物检测装置的研制
Development of a Passive-active Shuffler for 200 L Drum
【摘要】 研制了 2 0 0L桶装α废物检测装置 ,给出了装置性能的初步测试结果。装置可工作于无源和有源两种方式 ,适合测量 2 2 0L以下桶装α废物。无源工作方式下的探测下限为 1mg2 40 Pueff。
【Abstract】 A passive active shuffler for measuring 200 L drum containing uranium and transuranic waste has been constructed.Its principle,configuration, specifications and preliminary test results are described. The instrument can work at two modes:passive mode and active mode. At passive assay mode, the detection limit is about 1 mg 240 Pu eff . It can work at the active mode with a 252 Cf source.
【关键词】 α废物;
有源无源方式;
探测下限;
【Key words】 uranium and transuranic waste; passive active mode; detection limit;
【Key words】 uranium and transuranic waste; passive active mode; detection limit;
- 【文献出处】 原子能科学技术 ,Atomic Energy Science and Technology , 编辑部邮箱 ,2002年01期
- 【分类号】TL816
- 【被引频次】5
- 【下载频次】89