甘油-水溶液导热系数和浓度的快速测定
Rapid Measurement of Thermal Conductivity and Concentration of Glycerine-Aqueous Solution
【Abstract】 The thermal conductivity of glycerine aqueous solution was measured at 20 ℃ by means of a transient method with error in parallel analysis <1%. The equation correlating the concentration with thermal conductivity was presented . The time of measurement was 1 s. The method avoids the heat convection of liquid sample due to its rapidity and is promising for on line analysis in production control.
【关键词】 导热系数;
瞬时法;
甘油-水浓度测定;
【Key words】 thermal conductivity; transient method; glycerine aqueous solution;
【Key words】 thermal conductivity; transient method; glycerine aqueous solution;
【基金】 陕西省教育厅专项科研基金资助项目 (95ky0 8)
- 【文献出处】 应用化学 ,Chinese Journal of Applied Chemistry , 编辑部邮箱 ,2002年08期
- 【分类号】O645
- 【被引频次】10