节点文献

差示扫描量热法测定肌醇纯度

Determination of Purity of Inositol by DSC Method

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 纪雷孙忠松王岩崔鹤

【Author】 JI Lei, SUN Zhong -song, WANG Yan and GUI He( Chem. & Mine. Lab. , Qingdao Entry - Exit Inspection and Quarantine Bureau, Qingdao 266002)

【机构】 青岛出入境检验检疫局化矿金实验室青岛出入境检验检疫局化矿金实验室 青岛 266002青岛 266002青岛 266002

【摘要】 目的:使用差示扫描量热法(DSC)对肌醇纯度进行测定。方法:使用密封式铝坩埚封装样品,测定的最佳条件为升温速率约1℃·min-1 ,样品量约2.5 mg,氮气流速为20~40 mL·min-1。结果:纯度测定的PSD为0.02%,通过F检验及t检验,该方法与药典法无显著差异。结论:该方法简便、快速、准确,适合肌醇产品的定量测定。

【Abstract】 Objective: The differentical scanning calorimetry ( DSC) technique for the purity determination of in-ositol was introduced and the influencing factors were investigated. Method: Hermetic aluminum pan was used to encapsulate samples, the optimal testing conditions were: heating rate≈1℃·min-1, sample weight≈2.5 mg and nitrogen gas flow rate =20 -40 mL· min-1 . Result: The experiments yielded good result: there were no significant variation between the results obtained by DSC and Pharmacopoeia method by F - test and t - test, and RSD was 0. 02%. Conclusion: Determination of purity of inositol by DSC is a practical method for its accuracy, convenience and practicality.

  • 【文献出处】 药物分析杂志 ,Chinese Journal of Pharmaceutical Analysis , 编辑部邮箱 ,2002年02期