节点文献
炼油厂含硫污水汽提塔的模拟计算
SIMULATION CALCULATION OF SOUR WATER STRIPPING COLUMN IN REFINERY
【摘要】 针对炼油厂含硫污水汽提塔的特点 ,修正三对角矩阵算法 ,利用适当的逸度系数及活度系数求解 ,模拟计算结果与实际基本相符。在指导济南石化、洛阳石化等 8家企业的扩产改造中 ,用此模拟结果设计污水汽提塔取得良好的效果。
【Abstract】 The characters of sour water stripping column in refinery were studied. The amended triple diagonal matrix algorithm and the feasible method of solving fugacity coefficient and activity coefficient were used to calculate the column. This result of simulation was basically conformable with the practice and has been applied to direct the design of revamping of sour water stripping columns for eight petro chemical plants in China with an acquired well effect.
【关键词】 含硫污水;
汽提塔;
模拟;
逸度系数;
活度系数;
【Key words】 sour water; stripping column; simulation; fugacity coefficient; activity coefficient;
【Key words】 sour water; stripping column; simulation; fugacity coefficient; activity coefficient;
【基金】 河北省自然科学基金项目 (2 0 0 0 0 5 ) ;国家科技攻关计划资助项目 (2 0 0 1BA3 2 613 )
- 【文献出处】 石油学报(石油加工) ,Acta Petrolei Sinica (Petroleum Processing Section) , 编辑部邮箱 ,2002年05期
- 【分类号】TE96
- 【被引频次】11
- 【下载频次】355