节点文献

紫外分光光度法测定粗蒽中菲的含量

Determination of phenanthrene in crude anthraquinone by UV-spectrophotometer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 毛磊梁文懂范文英周学鹰

【Author】 MAO Lei 1,LIANG Wen dong 1,FAN Wen ying 1,ZHOU Xue ying 2(1.Wuhan University of Science and Technology, Wuhan 430081,China;2.Wuhan Iron and Steel Company,Wuhan 430080,China)

【机构】 武汉科技大学化工与资源环境学院武汉钢铁集团公司 湖北武汉430081湖北武汉430080

【摘要】 采用环己烷作为溶剂 ,在 0 .0 2 g/L ,2 93nm波长下用紫外分光光度法测定武钢粗蒽产品中菲的含量 ,得到较为理想的结果。该法相对标准偏差 2 .70 % ,平均回收率为 10 1.5 2 % ,RSD为 2 .5 9%。本法简便、快速 ,结果可靠 ,适于粗蒽中菲含量的测定

【Abstract】 A determination of phenathrene in crude anthraquinone by UV Spectrophotometer has been studied. Cyclohexane is applied as solvent and wavelength of the determination is 293 nm. The method has the precision of 2.70% RSD. The average recovery is 101.52% with RSD of 2.59%. The method is characterized by simplicity,quick determination and better repeatability, and can be used for the determination of phenathrene in crude anthraquinone.

【关键词】 粗蒽紫外分光光度法
【Key words】 phenathrenecrude anthraquinoneUV spectrophotometer