【摘要】 根据谏壁电厂 9#机组改造后热力试验的有关数据 ,应用等效焓降法对回热系统进行了经济性分析计算 ,同时也分析了不明泄漏量和中压缸效率的影响 ,对进一步提高机组经济性有一定参考价值。
【Abstract】 According to the related data of heat experimentations put up on the improved #9 unit in Jianbi Power Plant, this paper used equivalent heat fall method to analyze and calculate its heat economy; at the same time it analyzed infections from the unknown leak and the efficiency of mid-press tank, which are valuable for improving the unit heat economy further.
【关键词】 性能试验;
回热系统;
热力系统分析;
等效焓降;
热经济性分析;
【Key words】 Performance experiment; Regenerative heating system; Thermodynamic system analysis; Equivalent heat drop; Thermal economy analysis;