开式系统中变速泵的节能分析
Analysis on energy saving of variable speed pumps in an open system
【摘要】 变速泵在开式和闭式管路中的节能效果不同 ,引起这种差别的原因是开式系统受水的静压作用改变了泵的效率。分析了开式管路系统中变速泵的节能效果并给出了计算实例
【Abstract】 The effects of energy saving of variable speed pumps in the closed circuit is different from those in the open pipeline system. The reason is that there is a static head in the open system causing the pump efficiency varying. Analyses the energy saving effects of variable speed pumps in open systems and provides calculation examples.
- 【文献出处】 暖通空调 ,Hv & Ac , 编辑部邮箱 ,2002年01期
- 【分类号】TU832.2
- 【被引频次】49
- 【下载频次】314