【作者】 程殿彬

【Author】 CHENG Dian-bin (Tianjin Dagu Chemical Co.,Ltd.,Tianjin 300450,China)

【机构】 天津大沽化工责任有限公司 天津300450

【摘要】 介绍了如何在离子膜运转 1年后及离子膜运转后期推算换膜最佳时间 ,并计算了换膜费用、年增电耗费等。认为应根据膜实际运行情况 ,在未达换膜经济时间时 ,也要考虑换膜。并提出提前换膜的注意事项

【Abstract】 A method of calculating the optimum time to replace the membrane after running for one year or at later stage of running was introduced.The cost of replacing membrane and the increase of electricity cost per year were calculated.Based on the practical running conditions of membrane,the replacement of membrane should be also considered although the economical time wasnt up.Points for attention were raised if replacement of membrane in advance was necessary.

【关键词】 离子膜更换最佳时间电解槽
【Key words】 ion exchange membranereplacementoptimum timeelectrolyzer