【摘要】 对美国 A ndersen酸雨采样器与国产酸雨采样器在 p H、电导率、雨量三方面的采样性能作了比较试验 ,结果表明监测数据基本一致 ,其中 p H值的可比性最好 ,相关系数达到 0 .99;A ndersen酸雨采样器采集的样品其电导率普遍低于国产酸雨采样器 ,说明该仪器在防颗粒物干扰方面性能较好
【Abstract】 Sampling capabilities of Andersen acid rain sampler and guotai acid rain sampler were compared. Monitoring data of pH, conductance and rainfall showed that the results were consistent and pH value was most adjacent with correlation coefficient equal to 0.99. The conductance of samples collected by Andersen acid rain sampler was normally lower than Guotai acid rain sampler, so former was in possession of a better capability of resisting particles disturbance.