节点文献
DG1025/18.2型“W”火焰锅炉冷态试验
Cold test of W-firing boiler DG1025/18.2
【摘要】 介绍了韶关发电厂DG10 2 5 / 18 2 Ⅱ 10型“W”火焰锅炉燃烧技术特点及“W”型火焰锅炉冷态试验模化技术 ,根据其火焰为“W”型和燃烧对称的燃烧特点 ,对该炉的冷态试验内容与方法进行了初步的探讨及分析 ,认为“W”型火焰锅炉的冷态试验应包括静态检查和炉内配风调平
【Abstract】 This paper describes the combustion technical features of W firing boiler DG1025/18 2 Ⅱ10 in Shaoguan Power Plant and the cold test modular technology of W firing boilers. The cold test content and manner of the boiler are approached based on its features of W shape flame and symmetrical combustion. It is indicated that the cold test of the boiler should consist of static check and furnace air distribution.
- 【文献出处】 广东电力 ,Guangdong Electric Power , 编辑部邮箱 ,2002年02期
- 【分类号】TK229.6
- 【被引频次】4
- 【下载频次】96