急性实验性脊髓损伤的TSE序列优化
Optimization MR sequences in acute spinal cord injury model
【摘要】 目的:探讨MRI不同序列对急性脊髓损伤模型中的病变显示价值。方法:对12只中国家兔建立脊髓液压损伤模型,伤后72h内行MRI扫描,分析比较自旋回波、小角度翻转激发、快速自旋回波序列于创区脊髓的影像学表现。结果:脊髓损伤后于创区脊髓MR表现呈高低信号混杂、结构紊乱。其中快速自旋回波的T2WI对于创区脊髓显示的准确率(90%)及创区脊髓信号强度差值(372±22.68)均高于其他几种序列(P<0.01)。结论:快速自旋回波的T2WI序列矢状面可显示创区脊髓不同信号表现,横断面可显示创区中心结构混杂。
【Abstract】 Objective:To analyze the ability of different MRI sequences for evaluation of experimental spinal cord injury.Methods:12 rabbits with induced spinal cord injury model by fluid percussion were performed 72h later MR scanning with SE(spin echo),STIR(short time inverse recovery),FLASH(flip low angle shoot)and TSE(Turbo spin echo)sequences.The imaging findings on different sequences were analyzed and compared.Results:MRI of the spinal cord injury showed mixed signal and deranged structure of the injured spinal cord. TSE T2WI was the highest in the diagnostic accuracy (90%) and provided high contrast(372±22.68) between the normal and injured spinal cord among those sequences.Conclusion:TSE T2WI can document different signal intensity on sagittal plane and the derangement of the central structure of the injured spinal cord on the axial plane.