节点文献

我国冷冻系统水冷设备污垢影响的能量损失研究

THE RESEARCH ON ENERGY LOSS CAUSED BY THE FOULING OF WATER COOLERS OF REFRIGERATING SYSTEMS IN CHINA

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 俞天兰蒋少青刘桂英支校衡彭德其俞秀民张琳

【Author】 Yu Tianlan Jiang Shaoqing Liu Guiying et al(Mechanical Clean Institute,Zhuzhou Institute of Techonology,412008)

【机构】 株州工学院机械清洗研究所株州工学院机械清洗研究所 株州412008株州412008

【摘要】 介绍了较少污垢冷冻系统水冷器的传热系数实际测试工作 ,结合文献数据研究水垢引起的传热效率下降 ,并计算分析由此引起的冰机压缩功耗上升比例为 7%左右 ,根据年鉴资料从宏观上推算 ,电耗损失高达每年 9 38亿元 ,建议大力推广自动清洗防垢技术。

【Abstract】 This paper states the actual measurement of the overall coefficient of heat transfer of water coolers with a little fouling in refrigerating systems.Combined with certain document data,the drop of the coefficient caused by the water fouling is researched.The increase in pressure work is analyzed and calculated,which is caused by the drop of the coefficient.The consumption is increased by about 7%.According to the yearbooks the power consumption is calculated from the macro point of view and reaches more than 4 billion dollars.It is suggested that the on line self cleaning fouling technology should be used widely.

【关键词】 污垢自动清洗水冷器经济学评估
【Key words】 foulingself cleanwater coolereconomicsassessment
【基金】 教育部资助的科学技术研究重点项目 编号 0 0 2 0 8
  • 【分类号】TB61
  • 【被引频次】11
  • 【下载频次】61