节点文献

FA-ELISA检测血吸虫病人短程抗体试剂盒近期疗效考核价值的研究

FURTHER EVALUATION OF CHEMOTHERAPEUTIC EFFICACY IN SHORT PERIOD AFTER SCHISTOSOMIASIS TREATMENT BY FA-ELISA DIAGNOSTIC KIT OF DETECTING SHORT TERM ANTIBODY

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 梁幼生朱荫昌宁安戴建荣徐明杨小红华万全熊玉霞高祖禄胡启龙

【Author】 Liang Yousheng 1,Zhu Yinchang 1,Nin An 2, Dai Jianrong 1, Xu Ming 1, Yang Xiaohong 1, Hua Wanquan 1, Xiong Yuxia 3, Gao Zulu 2, Hu Qilong 2,1 Jiangsu Institute of Parasitic Diseases, Wuxi 214064; 2 Jiangxi Institute of Parasitic Diseases;

【机构】 江苏省血吸虫病防治研究所!无锡214064江西省寄生虫病研究所江西省波阳县血吸虫

【摘要】 目的 进一步评价日本血吸虫虫卵组分抗原 (10 7~ 12 1k Da)酶联免疫吸附试验 (FA-EL ISA)试剂盒的近期 (治愈后 2、4个月 )疗效考核价值。方法 非感染季节现场筛选粪阳病人 6 1例 ,分别在吡喹酮治疗前及治疗后 2、4个月做加藤氏法粪检和 FA- EL ISA、SEA- EL ISA,配对比较不同感染度病人阴转率。结果 治疗前 FA- EL ISA的检出率为 93.44 % ,SEA- EL ISA为 98.36 % ;治愈后 2个月和 4个月病人 FA- EL ISA的阴转率分别为 40 .35 %和 5 4.38% ,SEA- EL ISA则为1.6 7%和 3.33% ,两种方法间差异非常显著。 FA- EL ISA对重感染病人 (EPG>10 0 )的阴转率分别为 2 2 .2 % (2 / 9)和 33.3% (3/ 9) ,显著低于轻感染者。结论  FA- EL ISA短程抗体诊断试剂盒对治愈后 2个月、4个月者同样有较高疗效考核价值 ,而病人的感染度似可影响阴转率

【Abstract】 Objective o f Turther evaluate the chemotherapeutic efficacy in short period (2 months and 4 months) after schistosomiasis treatment by fraction antigen (107~121kDa) ELISA (FA ELISA) diagnostic kit for detecting short term antibody. [WT5”HZ]Methods [WT5”BZ]Sixty one of positive cases of schistosomiasis by Kato Katz faeces technique from two endemic villages in Jiangxi were treated with praziquental in uninfection season, then detected again by Kato Katz faeces technique at 2 months and 4 months post treatment, and tested by FA ELISA and routine SEA ELISA before and after treatment, comparing the positive and negative rates between the two assays. [WT5”HZ]Results [WT5”BZ]The positive rate of 61 cases before treatment with FA ELISA was 93.44%,98 36% with SEA ELISA At 2 months and 4 months after treatment the reverse negative rates were 40 35% and 54 38% with FA ELISA, were 1 67% and 3 33% with SEA ELISA respectively. There was significant difference between the two assays. The reverse negative rates in heavy infection cases (EPG>100) were 22 2%(2/9) and 33 3%(3/9) respectively with FA ELISA. It was much lower than that in light infection cases. [WT5”HZ]Conclusion [WT5”BZ]The FA ELISA has high value in evaluation of chemotherapeutic efficacy in short period after schistosomiasis treatment. The infection intensity of cases could impact the reverse negative rate.

【基金】 国家“九五”攻关项目!(编号 96 -90 6 -0 4-4 )的部分资助;UNDP/ WHO/TDR研究与培训奖学金资助!(编号 M8/ 181/ 4/ L2 86 )
  • 【文献出处】 中国血吸虫病防治杂志 ,Chinese Journal of Schistosomiasis Contral , 编辑部邮箱 ,2001年02期
  • 【分类号】R532.21
  • 【被引频次】15
  • 【下载频次】37
节点文献中: 

本文链接的文献网络图示:

本文的引文网络