节点文献
空调TAB调试影响因素的分析
Analysis of factors that are influential in HVAC testing adjusting and balancing
【摘要】 本文以实际工程为背景 ,分析了两种常用空调风系统的调试方法 :分步调节法和比例平衡法的优缺点 .对空调风系统中总风量及风口风量等存在的问题提出了相应的解决办法 .这些办法在实际工程的调节中起到了积极的作用 ,保证了系统调节精度能达到± 5 %以内
【Abstract】 Two typical methods of HVAC testing adjusting and balancing were introduced basis on practical project:stepwise method and proportional balancing method.Some solutions were given to testing total airflow and outlet airflow of HVAC air system.It has good effect on project and ensures the testing accurate of the system below ±5%.
【关键词】 分步调节;
比例平衡;
水力平衡;
【Key words】 stepwise method; proportional balancing method; hydraulic balancing;
【Key words】 stepwise method; proportional balancing method; hydraulic balancing;
- 【文献出处】 天津城市建设学院学报 ,Journal of Tianjin Urban Construction Institute , 编辑部邮箱 ,2001年02期
- 【分类号】TU831
- 【被引频次】6
- 【下载频次】35