节点文献
大尺寸四角切圆燃烧锅炉汽温偏差原因分析及措施
An Analysis of the Cause Leading to Steam Temperature Deviation in a Large-sized Tangentially Fired Boiler and Measures Taken for Its Alleviation
【摘要】 通过对锅炉热力特性试验和热力计算的全面比较 ,并对其进行分析研究 ,把通常设计在后屏至末级的连接管由交叉形式改为平行方式 ,实际运行表明 :其改动是成功的 ,效果显著。
【Abstract】 A comprehensive comparison was conducted of the results of the thermodynamic testing of a boiler with those of the boiler thermodynamic calculation followed by a pertinent analytic study. On this basis the pipe connecting a rear panel to the last row of a tube bank was changed from a cross connected form to a parallel connected one. Ensuing operation of the modified boiler indicates that such a modification has been highly successful.
【关键词】 锅炉;
切圆燃烧;
汽温偏差;
交叉连接管;
【Key words】 tangentially fired boiler; steam temperature deviation; cross connected pipe;
【Key words】 tangentially fired boiler; steam temperature deviation; cross connected pipe;
- 【文献出处】 热能动力工程 ,Journal of Engineering for Thermal Energy and Power , 编辑部邮箱 ,2001年03期
- 【分类号】TK229.6
- 【被引频次】1
- 【下载频次】98