节点文献

冷原子荧光法测定聚苯乙烯食品包装材料中汞

DETERMINATION OF TRACE AMOUNTS OF MERCURY IN POLYPHENYLETHYLENE FOOD PACKAGING MATERIAL BY COLD VAPOUR ATOMIC FLUORESCENCE SPECTROMETRY

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 金米聪颜金良符展明范建中王立

【Author】 JIN Mi cong, YAN Jin liang, FU Zhan ming, FAN Jian zhong, WANG Li (Ningbo Sanitation and Anti epidemic Station Ningbo 315010)

【机构】 宁波市卫生防疫站!宁波315010

【摘要】 提出了冷原子荧光法测定聚苯乙烯食品包装材料中汞的新方法。采用甲苯溶样 ,以 3g· L-1的硫代硫酸钠溶液反萃 ,反萃液经高锰酸钾溶液氧化 ,氯化亚锡还原。该法仪器价廉、灵敏、准确、快速。RSD<4.3% ,回收率为 90 .0 %~ 1 0 2 .0 %。

【Abstract】 A method for determining mercury in polyphenylethylene food packaging material is presented in this paper. The sample is dissolved with toluene, and mercury is stripped with Na2S2O3 solution, and the organic substances in the stripped solution is then oxidized by KMnO4. Mercury is then determined by cold vapour atomic fluorescence spectrometry. The method is convenient, sensitive and rapid. The RSD is less than 4.3%, and recoveries are in the range of is 90.0%~102.0%.