【摘要】 简要地讨论了北京谱仪-Ⅱ(BES-Ⅱ)飞行时间计数器(TOF)数据的离 线刻度.利用J/φ能区的电子对事例仔细完成的离线刻度与校正结果表明,新的 TOF时间分辨达到σTOF=180ps.由此大大增强了对带电粒子的识别能力.对 于3σ的π/K分离其动量可以达到0.93GeV/c.

【Abstract】 Data offline calibration and reconstruction for the BES- Ⅱ TOF system are reported in this paper. After applying calibration constants to correct the measured raw data, a the resolution of 180 ps is obtained for the new TOF system. The power of charged particle identification is improved. The momentum for the 3σπ/K separation goes up to 0. 93 GeV/c.