节点文献

锅炉水冷壁散管防护保温结构设计及应用

The Protective Insulating Layer Structure Design and Application for the Waterwall Separate Tubes of Boiler

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【摘要】 为防止水冷壁散管腐蚀破坏 ,需要对其采取防护措施。在对原防护结构破损脱落原因探讨基础上 ,提出了 2 0 0 8t/h锅炉水冷壁散管新的防护结构设计方案 ,并研制了HCG特种混凝土防护材料。通过采用防护材料、预留膨胀缝、丝网加固、固定件连接焊接等技术措施 ,累计 36 0 0h的运行结果表明 ,该结构设计合理 ,防护材料完整 ,无脱落变形 ,对水冷壁散管起到了有效的防护作用。

【Abstract】 In order to prevent the corrosive destruction of waterwall separate tubes, it is necessary to adapt protection measures for them. Based upon the exploration on the causes of breakage and drop of original protection structure, a new protection structure design scheme for 2 008 t/h boiler waterwall separate tubes is put forward, and the HCG special concrete protective materials had been researched. Through adapting new protective materials, reserving expansive seams, reinforcing with silk screen, connecting firmwares by welding and other technical measures, the running result of 3 600 h. shows that, such structure design is reasonable, the protective materials are integral and without drop or deformation, so it acts effective protection on the waterwall separate tubes.

  • 【文献出处】 东北电力技术 ,Northeastern Electric Power Technology , 编辑部邮箱 ,2001年09期
  • 【分类号】TK223.31
  • 【下载频次】57
节点文献中: 

本文链接的文献网络图示:

本文的引文网络