洛氏硬度计试验力误差对C标尺示值的影响
Effect of Test Force Error of Rockwell Apparatus on Indicating Value of C Scale
【摘要】 阐述初、主、总三种试验力误差对洛氏 C标尺高、中、低值的影响以及单方面地用调整块调整时所出现的必然现象。
【Abstract】 The effect of primary,main and overall test force errors on high,medium and low indicating values of Rockwell apparatus and the certainly phenomenon caused by adjustment with adjustment block only are described.
【关键词】 试验力误差;
C标尺;
示值;
杠杆臂比;
调整块;
【Key words】 Test force error; C Ruler; Indicating value; Ratio of lever; Adjustment block;
【Key words】 Test force error; C Ruler; Indicating value; Ratio of lever; Adjustment block;
- 【文献出处】 航空计测技术 ,Aviation Metrology & Measurement Technology , 编辑部邮箱 ,2001年01期