来宾电厂420t/h锅炉汽温偏低原因分析及技改措施的探讨
Cause Analysis for the Steam Temperature of 420t/h boiler in Laibin Power Plant being on low side and Discussion on Improvement Measures
【摘要】 对来宾电厂420t/h锅炉主蒸汽温度偏低的主要原因进行了分析,并根据实际运行条件提出了解决问题的方法。
【Abstract】 Main causes of the main steam temperatures of DG42Ot/h boiler in Laibin Power Plant being on low side are analyzed. On basis of actual operation conditions; solutions are pro- posed for such problem.
【关键词】 420t/h锅炉;
汽温偏低;
原因分析;
改进措施;
【Key words】 t/h boiler; steam temperature being on low side; cause analysis; improvement measures;
【Key words】 t/h boiler; steam temperature being on low side; cause analysis; improvement measures;