碱性体系氢化物发生-原子荧光光谱法测定矿物中的痕量硒

Studies of Seleium by HG-AFS in Alkaline Medium

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 艾军张平李强明黄冰海

【Author】 AI Jun , ZHANG Ping, LI Qiang ming, HUANG Bing hai (Department of Pharacy, Wuhan Instuitute of Chemical Technology, Wuhan, 430073)

【机构】 武汉化工学院制药系!武汉430073

【摘要】 对碱性体系氢化物发生 -原子荧光光谱法测定痕量硒的方法进行了探讨 ,研究了体系的最佳实验参数。与常规酸性体系氢化物发生 -原子荧光光谱法比较 ,本法能有效地消除大量铜、铁、钴、镍等过渡族元素的干扰 ,样品可不经分离直接进行测定。经对国家标样的分析验证 ,其测定值与推荐值吻合。方法的检出限为 0 .55μg/L,相对标准偏差为 4.1 2 % ,标准加入回收率为 99.8%

【Abstract】 The method for direct determination of seleium by hydride generation atomic fluorcescence spectrometry in alkaline medium has been established. The optimal conditions for hydride generation in alkaline medium were investigated. The interference from transition elements, such as copper, iron, nickel and cobalt were prevented due to the determination in alkaline solution. The proposed method was rapid and effective. The method has been applied to the determination of seleium in national standrad reference materials. The analytical results were in good agreement with the certified values. The detection limit was 0.55 μg/L for seleium. The precision was 4.12% (n=12). The recovery was 99.8%.

  • 【文献出处】 分析科学学报 ,Journal of Analytical Science , 编辑部邮箱 ,2001年01期
  • 【分类号】O657.31;O613.52
  • 【被引频次】8
  • 【下载频次】72