【摘要】 该文分析了娘子关电厂 3号炉大修后运行过程中发生炉内结渣和灭火的原因 ,介绍了通过燃烧调整解决炉内结渣和低负荷不投油稳燃的经验 ,对同类型锅炉的燃烧调整有借鉴作用。图 1
【Abstract】 The paper analyzes reasons why slugging and flame failures occurred during operation after an overhaul and describes experiences gained with combustion adjustments, that solved the slagging problem, and those in stabilizing low load, without resorting to combustion at fuel oil. The paper may serve as a reference for combustion adjustment work of boiler, of similar types. Fig 1, tables 7 and refs 4