410t/h锅炉燃烧调整试验研究

Studies of Combustion Adjustments of a 410t/h Boiler

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李东雄邢德山贾国璋郝瑞

【Author】 LI Dong xiong 1, XING De shan 1, JIA Guo zhang 2, HAO Rui 3 (1. Taiyuan Technical High School of Power, Taiyuan Shanxi 030013, China; 2. Niangziguan Power Plant, Yangquan Shanxi 045203, China; 3. Shanxi Academy of Power, Taiyuan Shanxi 030001,

【机构】 太原电力高等专科学校!山西太原030013娘子关电厂!山西阳泉045203山西电力科学院!山西太原030001

【摘要】 该文分析了娘子关电厂 3号炉大修后运行过程中发生炉内结渣和灭火的原因 ,介绍了通过燃烧调整解决炉内结渣和低负荷不投油稳燃的经验 ,对同类型锅炉的燃烧调整有借鉴作用。图 1

【Abstract】 The paper analyzes reasons why slugging and flame failures occurred during operation after an overhaul and describes experiences gained with combustion adjustments, that solved the slagging problem, and those in stabilizing low load, without resorting to combustion at fuel oil. The paper may serve as a reference for combustion adjustment work of boiler, of similar types. Fig 1, tables 7 and refs 4

【关键词】 锅炉结渣燃烧调整
【Key words】 boilerslaggingcombustionadjustment
  • 【分类号】TK227.1
  • 【被引频次】4
  • 【下载频次】65