节点文献

分光光度法测定飞来峡水库水中的铀、钍

Determination of U and Th by Spectrophotometric Method in Fresh-Water from Feilaixia Reservoir

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈志东邓飞林清陈德育刘瑛陈福亮

【Author】 Chen Zhidong Deng Fei Lin Qing Chen Deyu Liu Ying Chen Fuliang (Guangdong Environment Radiation Research and Monitoring Centre, Guangzhou,510300)

【机构】 广东省环境辐射研究监测中心!广州510300

【摘要】 用 Fe( OH) 3共沉淀淡水样中的铀和钍 ,经硝酸溶解后 ,用 2 3 5 N-环己烷萃取铀钍 ,在盐酸介质中用分光光度法分别测定飞来峡水库水样铀、钍的含量。结果表明 ,铀、钍的回收率稳定在 80 %以上 ,方法稳定可靠 ;飞来峡水利枢纽建成后库区水体中铀、钍的含量维持在以前的水平。

【Abstract】 U and Th in fresh water from Feilaixia Reservoir were co precipitated with Fe(OH) 3, dissolved by HNO 3, extracted by 235 N cyclohexane,and determined by Spectrophotometric Method.The results showed that the recoveries of U and Th were above 80%.The method is stable and reliable.There was no change in contents of U and Th in water samples compared with the results before the project.

【关键词】 飞来峡235N分光光度法
【Key words】 Feilaixia U Th 235 N Spectrophotometric Method
  • 【文献出处】 辐射防护通讯 ,Radiation Protection Bulletin , 编辑部邮箱 ,2001年01期
  • 【分类号】X837
  • 【被引频次】19
  • 【下载频次】290
节点文献中: 

本文链接的文献网络图示:

本文的引文网络